G4-MD-100-2P technical specifications
The technical specifications for the product are shown below.
 
 
Figure 4: G4-MD-100-2P rear
 
System
-
Deployment
Multi-100 Gb data center
Lights Out Management (LOM)
Yes
Redundant OS drive
Yes
OS drive hot swappable
Yes
OS drive size
2TB
Rail kit
Yes
Operating system
Windows 2012 R2
Physical
-
Height
2U
Width
21 in
Depth
25.5 in
Weight (with mounted rail kit or portable unit without a travel case)
56 lbs
Weight (handling or portable unit in a travel case)
62 lbs
Media
-
Monitoring interfaces
2
Speed
100G
Accepted transceivers 1
QSFP28
Performance
-
Aggregate performance
50 Gbps
Power
-
Redundant power supply
Yes
Input frequency
50/60Hz
Input voltage
100V-240V Auto Select
Operational current (amps)
4.42
BTU/hr
1808
Operational voltage
120V
Power dissipation (watts)
530
Relative humidity (non-condensing)
8% to 90%
Temperature (operating)
10°C ~ 35°C (50°F ~ 95°F)
Temperature (storage)
-40°C to 60°C (-40°F to 140°F)
Compliance
RoHS, FCC, CE

1  For SFP, the SFP may be any of Copper 10/100/1000, 1Gb SX/LX. For SFP+, the SFP+ may be any of 10Gb SR/LR. For QSFP+, the QSPF+ may be any 40Gb SR/LR/BiDi/Universal. For QSFP28, the QSFP28 tranceivers may be SR4, LR4, or BIDI.