Observer Analyzer : Observer Analyzer : GigaStor Control Panel : Mining data from your GigaStor : Analyzing multiple GigaStor probe instances from one GigaStor Control Panel
Analyzing multiple GigaStor probe instances from one GigaStor Control Panel
Combining the data of multiple GigaStor probe instances into one GigaStor Control Panel allows for quick and easy isolation of information.
One example where you might use this is if you need to find information but are unsure which GigaStor probe instance to query. Instead, you can combine the data of any GigaStor probe instances you have access to and perform just one query.
Note: The GigaStor Control Panel must be open for every GigaStor probe instance you want to combine for analysis.
To analyze multiple GigaStor probe instances from one GigaStor Control Panel:
1. On the Home tab, in the Capture group, click GigaStor.
2. Click Tools.
3. Click Select GigaStors for Combined Indexing.
4. Choose two or more probe instances and click Apply.
If a particular GigaStor probe instance is not listed, ensure the GigaStor Control Panel for that instance is open and try again.
5. Click Update Reports to start combining index data.
6. After the process completes, the currently open GigaStor Control Panel is showing a real-time aggregate of multiple GigaStor probe instances.
 
 
 
After completing this task:
Simply use the combined GigaStor Control Panel the same way as a non-combined GigaStor Control Panel. See Using the GigaStor Control Panel for details.